| Particulars |
Description |
| System Rating |
1050 – 50A/12V |
| Capacity |
850VA |
| Operating DC Voltage |
12V |
| Nominal Grid Voltage |
230V |
| Battery Low Buzzer |
10.8V |
| Battery Low Cut |
10.5V |
| Battery High Cut |
16.5V |
| Grid Charging Voltage (Equalize) |
After 30Days |
| Grid Charging Current |
12A/15A |
| Grid Reconnect @ Battery Voltage |
11.8V |
| Output Phase |
1 Phase |
| Nominal Output Voltage |
220V±8% |
| Max. Output Current |
2.1A |
| Nominal Frequency |
50Hz±1% |
| Output Waveform |
Sine wave |
| Typical Efficiency |
≥82% |
| Maximum PV Power Recommended |
(150W/160W)x4 |
| Solar current max |
50A |
| Solar current min |
>3A (Below 3A, System will act like Solar Absent) |
| Protection |
Overload, Battery Low, Battery High, Output Short, Battery Reverse, Over Heat, Over frequency, Under Frequency, SPV High. |
| LED Indication |
System ON, (IT Mode, SMF/TUB, Boost Charging, DG Mode, Grid Charging) Enable/Disable. |
| Switches |
Reset for System ON/OFF, UP, Down, Back, Enter(For LCD Calibration) |
| Standard Compliance |
IP20 |
| Weight |
10Kg |
| Dimension L x W x H |
300x265x128 mm |